Smart.Industrial.Audit.Trail stamps every entry with the time and its UTC offset, keeps the previous value next to the new one and links each entry to the previous one with a hash. smart-audit-trail displays the entries, provides search and filters, exports the trail with its hashes, and verifies the hash chain. An entry that was altered, removed or reordered in a copy breaks the chain from that point on, and the component shows where. Neither the trail nor the component stores data; the application persists the entries and reloads them with Trail.from().
The setpoint of FIC-101 is a GMP-critical parameter, so a change requires a reason and an electronic signature (user jdoe, password operator1). The keypad rejects values outside 0–120, the signature panel requires a reason, and the audit trail records the change with both values and the signature. Click Show a tampered copy to alter one exported entry and see the chain break.
Keyboard: Tab to the rows, use the arrow keys to move, and press Enter to select a row and raise entrySelect. The Time column header sorts the entries. The integrity badge is a status message and a broken chain is announced to screen readers.